HBG Low NOx Burner

Parameters

    Large power range, power regulation ratio 10:1; Low NOx emission, air preheating Max.500℃. High flame outlet speed, up to 100 m/ SEC; Long life fire - resistant nozzle brick structure, using ignition; Burner ignition, UV detection flame, reliable and stable.

Expand All FOLD

Product Details

HBG

Model

060 – 500

Specification

A-Z

Version

/P

Liquid Gas

/N

Natural Gas

/C

Coke oven Gas, City Gas

/M

Mixed Gas

H

High Speed

M

Mid Speed

- P

Equipped With Ignition Gun

- U

UV Detection Type


Model

Power(×104kcal/h)

HBG-060

50

HBG-090

75

HBG-120

100

HBG-150

125

HBG-200

150

HBG-250

200

HBG-300

250

HBG-400

300

HBG-500

400